Notifications
You must be signed in to change notification settings - Fork 78
Description
Hi,
First, this is NOT an issue and like the LA processing frontend, you have created!
Now, I have made a few changes (still ongoing and testing) Would you be interested in them?
I have added a LA query option that will allow for:
- Give a name for the LA in use.
- Give the max amount of samples it can read.
- Tell the number of Lines it has.
- The line names (pins) can be set by the LA hardware.
- Give the highest baud rate it can run at.
The GUI now sends the query command to the LA and if the baud rate is different than the current one, it resets it. This is mainly for LA hardware that can easily do more than 115k. The line names sent back are used for the display. The display will be dynamically set for the number of lines (max of 8 for now) This is still on my to-do list but should be doable. Set the number of samples dynamically is still on the list to do as well.
I have added a status line to the bottom and set the window title bar with the current LA connected to it.
Let me know if you would care to use them.
Thanks for your work.
Scott